Inclou

Included

  • FOUNDATIONS AND SUPPLY CONNECTIONS

    Foundations for a flat and uncomplicated terrain. It includes sanitary slab of one block and a layer of gravel under the slab with a thickness of 10 cm.


    Supply connections. It includes derivations of the house installations from the ground floor slab up to a maximum distance of 15 linear metres in the direction of the public road.

  • STRUCTURE

    House structure through a 25 m YTONG BLOCK with interior wall cladding:


    a. 48 mm metal auxiliary structure

    b. Rockwool 50 mm

    c. Laminated gypsum board 15 mm

  • ROOF

    The upper termination of the house will be materialised through the configuration of a FLAT ROOF WITH TRUSSES


    1 – False ceiling: laminated gypsum boards

    2 – Vapor barrier (waterproofing)

    3 – Mitek truss

    4 – Rockwool based insulation

    5 – Waterproofing with sandwich panels to improve insulation

  • FAÇADE CLADDING / EXTERIOR FINISH

    SATE EXTERIOR FINISH


    Executed using ACRYLIC MORTAR (responsible for the rough finish of the surface).

  • FLOORING

    Installation on slab base depending on the project, with provision for connections and drains.


    Ground floor: Caviti insulation with 4 cm extruded polystyrene panels, in order to close  thermal bridges, with application of a subsequent compression layer of mortar. 

    It will be finished with AC4 laminated parquet flooring.

  • EXTERIOR CARPENTRY

    PVC carpentry with thermal bridge break and interior reinforcement.

    Till and turn windows, with double glazing. The thickness of the glass follows the sequence (4/16/4 mm).


    1.- Windows with manual blinds: width 120-140 cm. - height 118 cm

    2.- Picture windows: height 218 cm without blinds

    Available colour: white (Other colours available. 

    Price on request according to dimensions).

  • INTERIOR CARPENTRY

    Interior doors with monobloc solution made of MDF, semi-matt composition, smooth white colour.

  • PARTITIONS / INTERIOR FINISH

    The interior dividing elements are defined by the following configuration:

    • 48 mm plasterboard grid
    • Mineral insulation (WOOLROCK) 50 mm
    • Laminated gypsum board 15 mm

    The interior cladding will be executed by means of gypsum plastering, accompanied by the relevant coat of interior paint.


    Bathrooms: laying of ceramic tiles on the floor and wet areas (shower). In the rest,

    painting.



  • ELECTRICAL INSTALLATION

    The layout of the installation will be executed according to the calculations and design

    made in the Executive Project, based on the Low Voltage Regulations and the relevant Technical Instructions.


    The lighting will be by means of LEDs. The number of light points will be proportional

    to the surface area of the dwelling.


    Number of light points and switches included according to the project to comply with CTE standards.

  • KITCHEN

    Includes hydraulic and electrical pre-installation, tiles in wet areas, and an allocation of €3,000.00 for furniture without appliances. 

    A wide catalog of qualities and models is available to the client.

  • BATHROOM FITTING SUPPLIES

    Standard installation for each bathroom planned in the project:


    STANDARD BATHROOM –


    / ROCA OR SIMILAR WASHBASIN BRAND

    / MIRROR

    / STORAGE CABINET FOR BATHROOM

    / WASHBASIN FAUCETS

    / TOILET, CISTERN, SEAT

    / SHOWER PLATE

    / SINGLE LEVER SHOWER FAUCETS

    / FIXED SCREEN


    A system based on aerothermal energy for domestic hot water supply (DHW) will be installed; 110L monobloc storage tank.

  • CLIMATE CONTROL

    HEAT PUMP – DUCTED COLLING

  • EXTERIOR

    It includes the pavement around the perimeter of the house.


    Fence included:

    Street side: wall + car sliding door and entrance door

    Other sides:  metallic fence

Share by: